Wyle Laboratories Test Report

Historical SECO SEALS document – Post 6 is from the Wyle Laboratories Test Report for “Repeated Assembly, Impulse and Vibration Impulse Tests on Voi-Shan Mfg, Company Flared and Flareless Connectors ½” Size“ dated March 31, 1959.

Following is an extract from that test report.